Page - 50/73 AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual
6) SLIP VALUE
Hz value with two decimal digit. This is the slip between the frequency and
the speed of the motor (SLIP VALUE = FREQUENCY-ENCODER).
7) COSFI
From 0.00 to 1.00. This is a coarse extimation of the Power Factor (cosf
between the voltage and the current in the motor.
8) CURRENT RMS
Ampere value. Root Mean Square value of the line current in the motor.
9) BATTERY CURRENT
Ampere value. This is a coarse calculation (not a measurement) of the
battery current.
10) BATTERY CHARGE
Percentage value. It supplies the residual charge of the battery as a
percentage of the full charge level.
11) TEMPERATURE
°C value. This is the temperature of the inverter base plate. This temperature
is used for the HIGH TEMPERATURE alarm detection (see 14.1.7.1).
12) MOTOR TEMPERATURE
°C value. This is the temperature of the motor windings picked up with an
analog sensor inside the motor. Normally this sensor is a PTC Philips
KTY84-130. This temperature is used only to raise a warning in the hand set
when the motor temperature overtakes the MOTOR OVERTEMP setting.
13) ACCELERATOR
From 0.0V to 5.0V. The voltage on the wiper of the accelerator (CPOT on
CNB#10) is halved inside the controller and then recorded on this reading.
That means the actual wiper voltage is in the range 0 to 10V meanwhile the
corresponding ACCELERATOR reading is in the range 0.0 to 5.0Vdc.
14) BRAKE PEDAL POT
(Standard Version only). From 0.0V to 5.0V. When the MDI-PRC is absent,
the potentiometer connected to CPOTB on CNA#18 is used for a brake pedal
sensor. The voltage on the wiper of this brake pedal potentiometer (CNA#18)
is halved inside the controller and then recorded on this reading. That means
the actual wiper voltage is in the range 0 to 10V meanwhile the
corresponding BRAKE PEDAL POT reading is in the range 0.0 to 5.0Vdc.
15) LIFTING SWITCH
ON/OFF. This is the level of the CNB#9 digital input (Lifting request):
- ON +VB = When CNB#9 is closed to a battery (key) voltage, the
Lifting request is Active.
- OFF GND= When CNB#9 is not connected to a battery (key) voltage
(or it is connected to GND), the Lifting request is not
active.
16) DESCENT SWITCH
ON/OFF. This is the level of the CNB#8 digital input (Lowering request):
- ON +VB = When CNB#8 is closed to a battery (key) voltage, the
Lowering request is Active.