Page - 38/73 AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual
14) QUICK INV LOGIC
This option specifies the active level for the Belly switch input (CNB#7)
- OPTION#1: The quick inversion is executed when CNB#7 is closed to
a KEY voltage.
- OPTION#2: The quick inversion is executed when CNB#7 is opened
from a KEY voltage.
15) MDI-PRC
This option specifies:
- PRESENT: The MDI-PRC is connected to the AC1 via the CAN Bus:
the handling of the Hydraulics is specified on the TRUCK
TYPE setting below.
- ABSENT: The MDI-PRC is not connected to the AC1: the TRUCK
TYPE disappears from the SET OPTIONS function list.
16) VALVE 1 TYPE
(MDI-PRC version only). This option specifies the EVP1 type. The EVP1 is
connected on the pin 8 of the MDI-PRC.
- OPTION#1: EVP1 is an On/Off valve.
- OPTION#2: EVP1 is a proportional valve.
17) VALVE 2 TYPE
(MDI-PRC version only). This option specifies the Electrovalove #2 type. The
EVP2 is connected on the pin 9 of the MDI-PRC.
- OPTION#1: EVP2 is an On/Off valve.
- OPTION#2: EVP2 is a proportional valve
18) TRUCK TYPE
(MDI-PRC version only). This option specifies the hydraulics handling when
the MDI-PRC is present:
- 1: Both the Main Lifting/Lowering pair (CNB#9 and CNB#8)
and the Aux Lifting/Lowering pair (CNA#14 and CNA#15)
are used to activate two Lifting/Lowering distinct circuits
(double forks truck).
Main Lifting enables both, the pump contactor on CNA#4
and a valve to re-direct the oil in the main hydraulics
circuit connected to the pin #4 of the MDI-PRC.
Main Lowering enables both, an On/Off descent valve on
CNA#6 and a valve to re-direct the oil in the main
hydraulics circuit connected to the pin#4 of the MDI-PRC.
Aux Lifting enables both, the pump contactor on CNA#4
and a valve to re-direct the oil in the aux hydraulics circuit
connected to the pin #6 of the MDI-PRC.
Aux Lowering enables both, an On/Off descent valve on
CNA#6 and a valve to re-direct the oil in the aux
hydraulics circuit connected to the pin#6 of the MDI-PRC.
The valves are all On/Off type; no proportionality at all.
- 2: Only the Main Lifting/Lowering pair (CNB#9 and CNB#8)
is used to handle a fully Proportional function (there is one
proportional valve connected to the pin#8 of the MDI-PRC
used for both proportional Lifting and proportional
Lowering).
The CNB#9 input is the Lifting request to enable the
pump contactor on CNA#4.
The CNB#8 input is the Lowering request to enable the
descent valve on CNA#6.