- 15/18/20BT-7, 16/18/20B-7 Pump (05) Parameter setup.
CODE
ADJUSTMENTS
(service level)
Parameter explanation.
145
SET BATTERY TYPE
To selects the nominal battery voltage.
140
ADJUST BATTERY
Fine adjustment of the battery voltage measured by the controller.
254
THROTTLE 0 ZONE
It establishes a deadband in the accelerator input curve. See ac2 flash manual
252
THROTTLE X POINT
Parameter changes the characteristic of the accelerator input curve. See ac2 manual
253
THROTTLE Y POINT
Parameter changes the characteristic of the accelerator input curve. See ac2 manual
165
ADJUSTMENT #04
This parameter determines the motor temperature level at which the “Motor
temperature” alarm is signaled. The range is from 70°C to 160°C with 10°C steps. This
parameter must be adjusted only if the “Set temperature” (menu“Set option”)
parameter is programmed “Analog”.
253
PWM ON MAIN CONT
OFF: Battery voltage on main contactor coils. ON: Battery voltage reduced to 62%
254
PWM ON AUX OUT.
OFF: Battery voltage on aux output coils. ON: Battery voltage reduced to 62%
251
MAX/AUX
Aux out sensor maximum voltage recording.
For the elctr-hyd distributor version it can be adjusted from console/display
252
MIN LIFT
Lift sensor minimum voltage recording. For the lever version it can be adjusted using
PROGRAM VACC function (see ac2 flash manual).
For the elctr-hyd distributor version it can be adjusted from console/display (press
enter).
251
MAX LIFT
Lift sensor maximum voltage recording. For the lever version it can be adjusted using
PROGRAM VACC function (see ac2 flash manual).
For the elctr-hyd distributor version it can be adjusted from console/display (press
enter).
250
MIN LOWER
Lowering sensor minimum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
249
MAX LOWER
Lowering sensor maximum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
5%
0.5V
145?
63%
36%
4.6V
3.4V
0.8V
48 V
Values
60% / 25% (OPS)
51.7 V
OFF
OFF / ON (OPS)